Standard Liquid Nitrogen Freezers


S-90-AB, S1500-AB, S3000-AB, S5000-AB, S5000EH-AB Standard Liquid Nitrogen Freezers

Standard Liquid Nitrogen Freezer Internal
  • Round, space saving design.
  • Stainless steel, vacuum insulated vessel.
  • Wide lid opening for easy access to all racks.
  • Ease of operation plus flexibility to operate vapor storage, immersion storage or a combination of both to store any type or size of sample.
  • Each unit includes a liquid level, auto-fill and alarm system to provide security.


Request a Quote for a Standard Liquid Nitrogen Storage Freezer

CBS freezers offer a wide lid opening that allows easy access to all racks and provides an extensive variety of inventory solutions.
chest rack storage configurations Bag storage system configurations Jackson Lab rack systems Bag storage systems Chest Rack systems
S1500-AB Stainless Steel Standard Square Rack Configuration. 9,100 vial capacity S5000EH-AB Stainless Steel Baxter Fenwal 4R9951 Canister & Frame Configuration 1,140 Canister Capacity (250ml) Special LN2 Racks Cryo bag canisters and frames Chest Racks

Our 2301 controller is time tested, reliable and designed to keep your sample storage safe and secure.


New 16 Port Connector

0-5 volt outputs provide temperature & level data for connection to existing alarm/monitor system.

4-20 mA outputs provide temperature & level data for connection to existing alarm/monitor system.

Sequential and One-Fill-All-Fill input and output connection for filling systems.


New two level temperature display option

Temp. A displays temperature at the lid, approximately 11"(27.94cm).

Temp. B displays temperature inside the storage space, approximately 20"(50.80cm).

2301 Monitoring system for Custom BioGenic Systems Freezers


Additional Features

Records 12 alarms & events such as fill start, fill stop, etc. with dated time stamp, printed or displayed.

Download cryomonitor data files to PC and convert them to .csv files for use in Microsoft Excel.

Ethernet and auxiliary RS485 for future expansion.

Dedicated 24Vdc signal output to activate a third 24Vdc valve to control the LN2 supply.

Global Remote Alarm - Dry contact that switches during any alarm condition.

Data Log - Print or display Temp. A, Temp. B and level with date and time stamp.

     

Models / Specifications / Capacities

  S90-AB S1500-AB S3000-AB S3000EH-AB S5000-AB S5000EH-AB
LN2 Capacity (liters) 90 145 345 427 615 720
External Width in(mm) 18 (457) 22 (558) 34 (863) 34 (863) 44 (1,117) 44 (1,117)
External Depth in(mm) 18 (457) 31 (787) 43 (1,092) 43 (1,092) 52 (1,320) 52 (1,320)
External Height in(mm) 38 (965) 41 (1,041) 42 (1,066) 54 (1,372) 48 (1,219) 55 (1,397)
Usable Interior Height in(mm) 28 (711) 29 (736) 29 (736) 34.5 (876) 29 (736) 34 (863)
Usable Interior Diameter in(mm) 16 (406) 20 (508) 31 (787) 31 (787) 40 (1,016) 40 (1,016)
Maximum 2ml vial capacity 5,832 9,100 22,100 25,500 40,300 46,500
Maximum 50ml bag capacity 266 434 1,120

1,280

1,932 2,208

 